THE OIL AND GAS ACT
|
Regulations |
SCHEDULE C
(Subsections 9(1), 75(4), and 85(1)
Drilling and Production Regulation Table of Contents
Table of Minimum Distance Requirements
Note: The distances in the table are expressed in metres
To: | Well | Flame Type Equipment | Internal Compustion Engine | Flare Pit and Flare Stack |
Oil Storage Tank | Surface Improvement Except Well, Flow Line or Road Allowance |
Water Covered Area |
Road Allowance - Provincial or Municipal |
|
Air Shut Off | No Air Shut off | ||||||||
From: | |||||||||
Well | 5 | 25 | 5 | 10 | 25 | 25 | 75 | 100 | 45 |
BOP Manifold | 3 | -- | -- | -- | 15 | -- | -- | -- | 45 |
BOP Remote Control | 15 | -- | -- | -- | 15 | -- | -- | -- | 45 |
Flame- Type Equipment |
25 | -- | -- | -- | 25 | 25 | -- | -- | 45 |
Drilling Fluid Pit or Tank |
5 | 25 | -- | -- | 10 | -- | 75 | 100 | 45 |
Flare Pit and Flare Stack | 25 | 25 | 5 | 10 | -- | -- | 100 | 100 | 45 |
Emergency Storage Pit | 25 | 25 | -- | -- | 25 | -- | 75 | 100 | 45 |
Service or Test Tank | 25 | 25 | 5 | 10 | 25 | -- | 75 | 100 | 45 |
Oil Storage Tank |
25 | 25 | 5 | 10 | 25 | -- | 75 | 100 | 45 |
Vented Salt Water tank |
10 | 5 | 5 | 5 | 25 | -- | 75 | 100 | 45 |
Process Vessell | 25 | -- | -- | -- | 25 | 25 | 75 | 100 | 45 |
SCHEDULE D
Schdule D is repealed
SCHEDULE E
(Subsections 21(2) and 22(1), and clauses 24(1)(b) and 25(1)(a))
Requirements for a Drilling Blow-out Prevention System
Drilling and Production Regulation Table of Contents
Note:
1. In the diagrams,
"A" means an annular type blow-out preventer;
"R" means a single ram type blow-out preventer with one set of rams, either blank or for pipe;
"S" means a drilling spool with flanged side outlet connections for bleed-off and kill lines.
2. The line sizes indicated in the diagrams are the minimum nominal diameter required.
3. The portion of the bleed-off system from the drilling spool to the choke manifold must be constructed with flanged pipe connections. Threaded fittings may be used for the remainder of the bleed-off system.
4. The manifold system must be constructed to provide flow paths equivalent to those indicated in the diagram.
5. The bleed-off system must contain only the straight pipe, or 90° bends constructed of tees and crosses that are blocked on fluid turns.